Deckma Omd11 Manual 【Popular – CHEAT SHEET】

A central blower draws sample air from the engine through pipes to the measuring head. The Deckma OMD-11 manual contains a strict warning: The blower must create a negative pressure of approximately 200 mm water column. Any leak in the sampling tube results in false low readings.

| Component | Function | Common Manual Warning | | :--- | :--- | :--- | | Central Unit | Data processing & UI | Do not open while powered. | | Measuring Head | Optical detection | Clean lens annually. | | Blower Motor | Air aspiration | Check carbon brushes (if type M-4) every 10k hours. |


The OMD-11 requires regular cleaning to prevent fouling of the optical lenses.

Deckma OMD-11 is a legacy bilge alarm unit designed to monitor oil-in-water concentrations in marine environments, specifically to ensure compliance with IMO Resolution MEPC.60(33) standards. Core Function & Features

The OMD-11 uses a light-scattering measurement principle to detect oil droplets in a sample stream. Key technical highlights from the Solids Suppression deckma omd11 manual

: Designed to minimize false readings caused by non-oil contaminants like iron oxide, showing only 2 ppm for substances that older monitors might misread as 15 ppm. Dual Alarms

: Features two independent alarm circuits factory-set to 15 ppm, though they are field-adjustable between 2 and 15 ppm via front-panel buttons. Output Signals

: Provides a 0(4)–20 mA signal for external recording or remote metering. Compact Build

: The unit is IP 65 rated for protection against water jets and dust, measuring approximately Technical Specifications Specification Measurement Range 0 – 30 ppm (Trend indication up to 50 ppm) plus or minus 5 ppm around the 15 ppm threshold per IMO standards Power Supply 24V AC/DC (standard); other voltages available on request Sample Temperature Operates between positive 1 raised to the composed with power 60 raised to the composed with power Response Time Adjustable alarm delays between 2 and 20 seconds Operational Guidelines Installation A central blower draws sample air from the

: The unit should be mounted near the oily-water separator to minimize lag time. It requires a clean water source for flushing and mm OD piping for sample connections. Maintenance : Regular cleaning of the measuring cell is critical. The instruction manual

recommends using a dedicated cell cleaning brush and keeping spare desiccators and O-rings on hand. Calibration Check

: Proper function is verified using a Formazin polymer reference standard (typically 4000 FTU diluted to specific requirements) to ensure the monitor remains within the required accuracy limits. Shivtech Marine Control Systems & Services calibration kit contents INSTRUCTION MANUAL DECKMA HAMBURG Gmbh - YUMPU

Here’s a helpful, practical review of the Deckma OMD-11 Oil Mist Detector Manual — based on common user feedback and technical documentation standards. The OMD-11 requires regular cleaning to prevent fouling


The Deckma OMD-11 manual lists four distinct alarm states. Understanding these saves hours of panic.

| Alarm Type | LCD Display | Likely Cause (per manual) | Action | | :--- | :--- | :--- | :--- | | Main Alarm | ALARM + High value | Real oil mist (piston blow-by, bearing hot spot) | Slow engine, investigate crankcase. | | Pre-Alarm | PRE-ALARM | Rising mist or sensor drift | Increase monitoring, check scavenge fires. | | Fault Alarm | FAULT + Code E-01 to E-12 | Electronic failure, no airflow, lens broken | Check blower motor, wiring, fuse F2. | | Low Flow | FLOW ERROR | Blocked sampling tube, blower impeller stuck | Blow out tube with compressed air (careful: 0.5 bar max). |


Mounted directly on the engine crankcase door. The manual warns: Never install the measuring head where it is exposed to direct water spray or extreme vibration without dampeners. It contains: