Tool32 → ECU.PRG (generic) → job lesen_fgst → returns VIN via EDIABAS job layer.
INPA / NCS Expert / WinKFP / Tool32
│
[api32.dll] ← job & result handling
│
EDIABAS.DLL / EDIABAS.EXE (background process)
│
IFH-Service (ifhsrv32.exe) for network EDIC/ICOM
│
[OBD.INI / EDIABAS.INI / ECU.INI]
│
Physical layer (Serial COMx, USB:STD:OBD, REMOTE)
6.4.3 still heavily relies on Serial or STD:OBD definitions, not purely the Remote interface of newer versions. ediabas 6.4.3
EDIABAS 6.4.3 has no native mutex – if INPA and Tool32 run same time, expect IFH-0010: ACCESS LOCKED. Tool32 → ECU