Whether your party is online or in your living room, Rock Band Rivals has you covered. Play with friends in Online Quickplay, or make new ones with our online session browser. Join a Crew to compete in weekly online challenges in Rivals mode, perform your way through a rock documentary about your band in Rockudrama, plus get more than 50 free songs, new rock shop items, and access to future updates.
For engineers maintaining older TIA Portal V15 systems with SINAMICS MC drives, HSP047 SP10 (or its latest compatible version) is a critical download. Always retrieve it via Siemens Industry Support or the TIA Portal built-in package manager to ensure integrity and version compatibility.
Siemens MC Drives V15 HSP47SP10 (Hardware Support Package) is an essential update for TIA Portal V15
that enables the configuration of SINAMICS drives with firmware version
. While it is technically a support package rather than a standalone product, users frequently discuss it as a critical fix for project compatibility and hardware integration. Core Functionality Expanded Hardware Catalog : Adds support for SINAMICS G120 , and G110M units running firmware V4.7 SP10 New Motor Support : Specifically enables the use of SIMOTICS GP/SD (1FP1)
synchronous reluctance motors with G120 and G110M series drives. Unified Engineering
: Allows these drives to be managed directly within the TIA Portal environment instead of needing external tools like STARTER. Critical Installation Reviews & Issues Users on the Siemens Support Forum
have noted several technical hurdles regarding this specific package: Need link for SINAMICS Startdrive V15 Update 4 - SiePortal
If you are struggling with the HSP, note that Siemens recommends using SINAMICS Startdrive for newer projects. Startdrive is a dedicated add-on for TIA Portal that handles drives more comprehensively than an HSP. However, for V15, the HSP remains the standard method.
The Siemens MC Drives V15 HSP47SP10 is more than a routine patch. It is an essential update for any engineer maintaining or commissioning SINAMICS drives with TIA Portal V15. It closes critical bugs, adds support for newer hardware revisions, and ensures your motion control system operates with the latest safety and performance standards.
While TIA Portal V15 is no longer the newest version on the market (V18 and V19 are current as of 2025), many factories and OEMs still rely on V15 for legacy system stability. Therefore, having the latest HSP47SP10 is vital to avoid costly delays when replacing a faulty drive with a new one that ships with modern firmware. siemens mc drives v15 hsp47sp10 download new
Action Items:
By following this guide, you have ensured that your TIA Portal V15 environment is fully equipped to handle the latest Siemens motion control hardware. Stay updated, stay efficient, and keep your production lines moving.
Disclaimer: Siemens product names (TIA Portal, SINAMICS, HSP) are trademarks of Siemens AG. This guide is for informational purposes. Always consult the official Siemens manual (Article number: 109765432) for safety-critical installations.
The Siemens MC Drives V15 HSP47SP10 refers to a Hardware Support Package (HSP) specifically designed to integrate SINAMICS Firmware Version 4.7 SP10 into the TIA Portal Startdrive V15 environment. Technical Overview
Purpose: This package allows engineers to configure and use newer SINAMICS drive hardware and functional features that were not natively included in the original TIA Portal V15 hardware catalog.
Compatible Hardware: Primarily supports the integration of SINAMICS G120, G120C, G120D, G120P, and G110M units running firmware 4.7 SP10.
Key Feature: Enables the use of SIMOTICS synchronous reluctance motors (1FP1 series) with G120 and G110M drives within the V15 engineering environment. Installation Requirements
Prerequisite Software: You must have Startdrive V15 (Basic or Advanced) already installed on your system.
Update Dependencies: Installation of SINAMICS Startdrive V15 Update 1 is a necessary precondition for subsequent updates. For engineers maintaining older TIA Portal V15 systems
Re-installation: If you ever re-install Startdrive V15, the Support Package must also be re-installed to restore access to these specific drive versions. Download Resources
The necessary files are available through the Siemens SiePortal (formerly Industry Online Support): Startdrive Support Package: ID 109754382. SINAMICS Firmware v4.7 SP10: ID 109756820.
Note: Users often encounter errors (e.g., Siemens.MC.Drives.V15_HSP47SP10) when attempting to open older projects in TIA Portal V15 without this specific HSP installed. Need link for SINAMICS Startdrive V15 Update 4 - SiePortal
The hardware support package (HSP) you are looking for is the Startdrive V15 Support Package for SINAMICS Firmware Version 4.7 SP10. This specific update is required to resolve errors like Siemens.MC.Drives.V15_HSP47SP10:1.0.0.0.0 when opening projects in TIA Portal V15. Download and Access
You can find the official download and documentation through the Siemens Industry Online Support (SIOS) platform:
Primary Entry ID (109754382): The SINAMICS Startdrive V15 Support Package page contains the necessary HSP for firmware version 4.7 SP10.
Alternative Entry ID (109757590): Specifically lists the Support Package for Sinamics Firmware Version 4.7 SP10. Installation Requirements
Existing Software: Startdrive V15 must already be installed on your system before you can apply this Support Package.
Export Restrictions: Some versions of these HSP files (specifically "restricted" versions) require a successfully completed export check on the Siemens website before the download link becomes active. Installation Steps Siemens MC Drives V15 HSP47SP10 (Hardware Support Package)
Since Siemens requires a valid login for direct downloads, this post provides the official workflow, the exact technical identifiers, and where to find the file legally.
Solution: Go to Options > Support Packages, select the existing HSP47, and click "Uninstall". Then reboot TIA and try the SP10 version again.
⚠️ Warning: Do not download HSPs from third-party file-sharing sites. Only use official Siemens channels to avoid malware or corrupted files.
Method A – Direct via Siemens Support (Web)
HSP047_SP10_TIA_V15.zip
Method B – Inside TIA Portal (Recommended)
Method C – Via Siemens Industry Mall (for licensed users)
After restarting, verify the installation:
The Hardware Support Package (HSP) version 047 SP10 (HSP47SP10) enables TIA Portal V15 to directly configure, parameterize, and diagnose SINAMICS Motion Control (MC) drives without needing a separate STARTER or SCOUT commissioning tool. This HSP is essential for users working with drives like the SINAMICS S120, S210, V90, or G120 in MC applications.