Spo2 Assistant 3.1
Not all pulse oximeters work with SpO2 Assistant 3.1. The software relies on a standardized BLE GATT profile. Here is the official compatibility list as of the 3.1 release:
Right-click on the graph → Add Event → type label (e.g., “awake”, “position change”).
| Item | Typical Value / Action |
|---|---:|
| Normal SpO2 (adult) | 95–100% |
| Concerning SpO2 | <90% (seek care) |
| Perfusion Index concern | <0.5–1.0% |
| Spot-check wait | 10–30 seconds |
| Common error sources | Motion, nail polish, ambient light, cold fingers |
| Default alert example | 92% SpO2 |
If you want this tailored to a specific vendor’s SpO2 Assistant 3.1 (screenshots, exact menus, or policy text), tell me the product name and platform (iOS/Android/Windows). Also indicate whether to include step-by-step screenshots or export templates.
SpO2 Assistant 3.1 is a specialized software application designed to work with pulse oximeters—typically those manufactured by Contec Medical Systems—to monitor, record, and analyze blood oxygen saturation (SpO2) and pulse rate data. Core Functionality and Application
The primary purpose of SpO2 Assistant 3.1 is to provide a user-friendly interface for managing physiological data collected from compatible hardware. It serves as a bridge between a physical medical device and a personal computer, allowing for more detailed data visualization than a standard handheld device can provide.
Real-Time Monitoring: The software displays live data from connected pulse oximeters, including waveforms (plethysmograms), trend graphs, and bar charts.
Data Analysis: It allows users to review historical data to identify patterns or anomalies, which is particularly useful for overnight sleep monitoring to check for conditions like sleep apnea.
Reporting: Users can generate and print professional-grade reports. These reports often summarize SpO2 and pulse rate averages, minimum/maximum values, and instances where oxygen levels dropped below a certain threshold. Key Features of Version 3.1
While specific "long essay" documentation for version 3.1 may be part of internal user manuals, its recognized technical features include:
Device Connectivity: Supports automatic scanning and connection via USB or Bluetooth. spo2 assistant 3.1
Alarm Configuration: Users can set custom alarm limits for low SpO2 or irregular pulse rates. The software provides both visual and audible alerts when these thresholds are breached.
Waveform Freezing: A "freeze" function allows for the temporary pausing of live waveforms for closer inspection of a specific heartbeat or signal segment. Clinical Significance of SpO2 Monitoring
Understanding the data provided by SpO2 Assistant is critical for health management.
Normal Ranges: A healthy individual typically maintains SpO2 levels between 95% and 100%.
Hypoxemia: Levels falling below 90% are generally considered a sign of hypoxemia, a condition where there is insufficient oxygen in the blood, potentially requiring medical intervention.
Telemonitoring: Such software is increasingly used in "telemonitoring" setups for chronic conditions like COPD or asthma, enabling patients to share vital data with healthcare providers remotely.
For a more comprehensive look at your specific data, you can download the latest version or manuals from sites like Software Informer or check the U.S. Department of Veterans Affairs (VA) TRM for official tool profiles. If you'd like, let me know: If you need help interpreting a specific report?
If you are having trouble connecting your device to the software?
If you need a step-by-step guide for a specific feature like setting alarms? Blood Oxygen Saturation (SpO2) Assistant - VA.gov
SpO2 Assistant 3.1 is a specialized Windows-based software application designed to monitor, review, and analyze vital health data from compatible pulse oximeters. Primarily used with Contec and similar hardware, version 3.1 provides an interface for users to visualize blood oxygen levels (SpO2), pulse rates, and perfusion index (PI) in real-time. Key Features of SpO2 Assistant 3.1 Not all pulse oximeters work with SpO2 Assistant 3
This version includes several tools to help users manage their health data more effectively:
Real-Time Monitoring: Displays live data uploaded from a pulse oximeter, including waveforms (plethysmogram), trend charts, bar charts, and numerical parameter values.
Automatic Device Detection: Features an automatic scanning function that helps the software find and connect to compatible pulse oximeters via USB or Bluetooth.
Data Review and Analysis: In review mode, users can analyze stored data, view long-term trend charts, and generate detailed health reports.
Alarm Management: Allows users to set specific alarm prompts for SpO2 and pulse rate values, providing alerts if readings fall outside of a predefined "safe" range. How to Use the Software
To begin using SpO2 Assistant 3.1, follow these standard operational steps:
Connection: Attach your pulse oximeter to your computer using a USB cable or enable Bluetooth pairing. Ensure the device is turned on and, if necessary, set to a "wireless" or "upload" mode.
Device Sync: Open the application and select the "Connect Device" icon (often represented by a connector symbol). If the device is not found, verify the USB port or Bluetooth capability of your computer.
Data Import: For stored data, select the option to "View device stored data only" and click "Receive data" to import records into the local database.
File Management: Imported data is typically stored locally on your hard drive (often found in the AppData\Local\VirtualStore directory) in a proprietary .spo2 format. Technical Compatibility and Requirements If you want this tailored to a specific
Operating System: Designed specifically for Windows environments.
Hardware Support: Compatible with Contec devices (like the CMS50F) and other authorized pulse oximeters that use the same communication protocols.
Security Note: Because this is freeware that handles sensitive health information, users should take standard security precautions when using USB or Bluetooth connections and ensure data is protected in compliance with local regulations. Why SpO2 Monitoring Matters
A normal blood oxygen level typically ranges from 95% to 100%. Monitoring these levels is vital for: Blood Oxygen Saturation (SpO2) Assistant - VA.gov
Based on the name provided, "SpO2 Assistant 3.1" most likely refers to a specific version of PC software used to interface with medical pulse oximeters. These tools are commonly used to track oxygen saturation and heart rate data over time, often for patients with Sleep Apnea (COPD) or athletes monitoring performance.
Here is a guide on what this software is, how it generally works, and how to use it.
| Problem | Likely fix |
|---------|-------------|
| No waveform | Reposition finger sensor; warm hands |
| Bluetooth drops | Stay within 10 m; re-pair in device settings |
| Alarm keeps false-triggering | Increase “Stability time” to 5 sec in Alarm delay |
| Data not saving | Check storage permission; free up space |
SpO2 Assistant is a Windows-based application designed to download, analyze, and report data recorded by specific brands of pulse oximeters (such as Contec, ChoiceMMed, or Beurer).
| Problem | Solution |
|---------|----------|
| No Bluetooth connection | Restart oximeter; check app permissions; ensure device is not paired to another phone. |
| Unstable readings | Warm hands; avoid movement; sit still for 30 sec before measuring. |
| Missing sleep data | Keep phone within 3m of oximeter; disable battery saver for the app. |
| App crashes | Update to 3.1.1; clear app cache; reinstall if persistent. |