Systec It3 User Manual →

Step 1: Connect power. Step 2: Connect Ethernet to network with DHCP. Step 3: Power on; wait for LED pattern (describe). Step 4: Access web UI at http://192.168.1.100 (default) or discover via mDNS at it3.local. Step 5: Login with default credentials (admin / password123) — immediate password change required. Step 6: Run setup wizard: set hostname, network, NTP, update firmware.

The IT3’s 8 digital inputs can be programmed as interrupt sources. The manual links to a code example in C++ that uses the systec_dio.dll library. This is critical for high-speed event counting in manufacturing lines.

  • Connections & Interfaces
  • Quick Start — 10-minute setup
  • Configuration
  • Operation
  • Maintenance
  • Troubleshooting
  • Advanced Topics
  • Safety, Warranty & Support
  • Appendix

  • Manual solution: The noise likely comes from the membrane pump. Clean the pump's intake filter (located behind the front panel). Replacement interval: every 500 cycles or 12 months.

    The SysTec IT3 is a universal weighing terminal designed for industrial applications, particularly in harsh environments like food, pharmaceutical, and chemical processing. Core Hardware Features Rugged Housing : Stainless steel construction with IP69K protection

    rating, suitable for heavy washdown and extreme temperatures. Visual Interface 5-inch color TFT display

    (800 x 480 pixels) provides clear weight indication and multi-lingual operator prompts.

    : Numeric membrane keyboard with tactile feedback, supporting alphanumeric entries through multiple key assignments.

    : Integrated power supply for 110–240 V AC or 12–30 V DC (mobile use). Standard Operating Modes

    The terminal supports several specialized application programs: IT3 series weighing indicators

    Systec IT3 User Manual: The Complete Integration & Operation Guide

    The Systec IT3 stands as one of the most versatile weighing terminals in the industrial sector. Designed for harsh environments and complex data processing, it bridges the gap between simple scale indicators and full-scale industrial PCs.

    Whether you are a technician setting up a new unit or an operator looking for specific function codes, this guide serves as a comprehensive roadmap to the IT3 ecosystem. 1. Overview of the Systec IT3 Terminal

    The IT3 is a programmable weighing terminal available in multiple configurations, including wall-mount, desk-top, and panel-mount versions. It is primarily used for: Basic weighing and taring. Parts counting. Vehicle weighing (First/Second weight). Filling and batching control. Key Specifications Protection: IP65-rated stainless steel housing. Display: Bright, back-lit LCD for high visibility.

    Connectivity: Support for RS232, RS485, Ethernet, and Profibus/Profinet. Internal Memory: Storage for up to 10,000 weighing records. 2. Basic Operation & Controls systec it3 user manual

    Understanding the interface is the first step in the IT3 user manual. The Keyboard

    Zero Key: Resets the scale to zero (within defined legal limits). Tare Key: Subtracts the weight of a container.

    Function Keys (F1-F3): These are programmable. Depending on your specific software (e.g., BASIC or COUNT), these might trigger a printout or open a database.

    Numeric Keypad: Used for entering setpoints, IDs, or manual tare values. Switching On

    When you power up the IT3, it undergoes a self-test. Once the weight display appears, ensure the "Center of Zero" indicator is lit before placing any load on the platform. 3. Configuration & Calibration

    Note: Calibration should only be performed by qualified personnel, as it may affect the "Legal for Trade" status. Accessing Service Mode

    To enter the service menu for calibration or hardware configuration:

    Locate the service switch (usually found behind a protective screw on the back or bottom of the housing). Follow the menu prompts using the arrow keys. Step-by-Step Calibration: Select CALIBRATION. Ensure the scale is empty and capture the ZERO point. Place a known test weight on the scale.

    Enter the weight value via the keypad and press Enter to capture the SPAN. 4. Troubleshooting Common Error Codes If your IT3 displays an error, refer to these common codes: Error Code Error 1 Remove weight from the scale immediately. Error 2 Check for debris under the scale or a disconnected cable. Error 9 No Stability

    Ensure the scale is on a vibration-free surface. Check level. Error 30

    Analog-to-Digital converter failure; contact technical support. 5. Maintenance and Care To ensure the longevity of your Systec IT3:

    Cleaning: Use a damp cloth with mild cleaning agents. Avoid high-pressure washers directly on the cable entries.

    Cabling: Regularly inspect the load cell cables for fraying or moisture ingress. Step 1: Connect power

    Firmware: Ensure you are running the latest version of the Systec firmware to access new features and security patches. 6. Integration and Data Export

    One of the IT3’s strengths is its ability to talk to other systems.

    Printing: Configure the "Print" key to send a formatted ticket to a thermal or dot-matrix printer.

    PC Connection: Use the RTC (Real Time Configurator) software tool to backup settings or modify the print layout via your PC.

    Fieldbus: For PLC integration (Siemens, Rockwell), ensure the correct GSD or EDS files are loaded into your controller. Conclusion

    The Systec IT3 is a "set-and-forget" industrial tool, but its depth allows for complex automation when needed. Always keep your specific "Application Manual" (the software-specific guide) alongside this hardware manual to get the most out of your weighing system.

    The SysTec IT3 weighing indicator is a rugged, IP69K-rated terminal designed for harsh industrial environments, offering versatile, high-hygiene weighing, filling, and checkweighing applications. The user manual covers essential setup, including 110–240 V AC or 12–30 V DC power, 5 programmable softkeys, Alibi memory for legal-for-trade compliance, and PLC connectivity. Detailed technical specifications and documentation are available through the SysTec brochure center. Systec IT3 Weight Storage Guide | PDF | Computing - Scribd

    The IT1/3 needs an additional module (alibi memory) for storage => ASM. Interface can be Serial or Ethernet. When ethernetis used,

    Systec IT3 - Industrial Scales and Weighbridges in South Africa

    Mastering the SysTec IT3 weighing terminal starts with understanding its robust design and versatile operational modes. This industrial-grade terminal is engineered for harsh environments, featuring a stainless steel housing with IP69K protection.

    Whether you are setting it up for basic weighing, truck scales, or complex filling applications, this guide summarizes the essential sections of the Systec IT3 user manual to help you get started. 1. Key Technical Features

    Before diving into the menus, it is helpful to know what the hardware supports:

    Display: A high-contrast 5-inch (13 cm) color display provides clear weight readings and multi-lingual operator prompts. Connections & Interfaces

    Connectivity: Supports one or two analog scales with strain gauge load cells (up to 8 x 350 Ohm cells).

    Approvals: Weights & Measures (W&M) approved with a resolution of up to 10,000 d.

    Power: Options for 110–240 V AC (stationary) or 12–30 V DC (mobile/battery). 2. Basic Operations

    The sealed membrane keyboard includes dedicated function keys for daily tasks: Zeroing: Use the zero key to reset the scale when empty.

    Taring: Support for auto-tare and manual tare entry via the numeric keypad.

    ID Entry: Users can enter up to 20 additional IDs (e.g., order numbers, product codes) for better data tracking.

    Softkeys: Five programmable "softkeys" change their function based on the active weighing program. 3. Application Programs

    The IT3 comes with several preinstalled modes that change its behavior: Systec IT3 – Universal Industrial Weighing Terminal


    Match the communication baud rate with the receiving infrastructure (e.g., 9600 or 19200 bps). Mismatched baud rates will result in no data being received on the surface.

    In the world of high-precision laboratory equipment, few names carry as much weight as Systec. Known for their robust autoclaves and sterilization systems, Systec has set the standard for reliability and innovation. Among their most celebrated product lines is the Systec IT3—a series of steam sterilizers designed for demanding laboratory, production, and research environments.

    For technicians, lab managers, and quality assurance officers, the phrase "Systec IT3 user manual" is more than just a search term; it is the gateway to operational excellence, safety compliance, and equipment longevity. Whether you have just unboxed a new unit or are troubleshooting an error code, understanding the manual is non-negotiable.

    This article serves as an exhaustive companion to the official Systec IT3 user manual. We will break down its core sections, highlight critical safety protocols, explain programming nuances, and provide troubleshooting tips that every user should know.


    Dr. Dan Siegel

    To access our free resources please sign up below.

    Sign up for Dr. Dan Siegel's monthly update to stay informed about new courses, upcoming events, latest research, and newly released books.